As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
SHIP 3142 CORROSION FLOOR BEAM -Y1292 LOCATED BTW FR 65 TO FR 66 AT AFT GALLEY AREA (SSI 534147). REPLACED FLOOR BEAM LOC -Y1292 BTW FR64 TO FR66 AT AFT GALLEY AREA AS PER A319 SRM 51-72-11 AND A319 SRM 51-42-11 AND DWG D53472816 RELEASE DATE 18-DEC-06 ISSUE F, MEASURES OF CORROSION ARE: L=2.235 INCH W=0.385 INCH D=0.051 INCH.