What was found
SHIP 3162 UPPER FUSELAGE, FWD ENTRY AREA RIGHT SIDE, FLOOR PANEL 222FF, FWD SUPPORT STRUCTURE WITH CORROSION AT FR16 AROUND SCREW HOLE. CORRECTIVE ACTION: REPLACED WEB ASSY LOCATED AT UPPER FUSELAGE FWD ENTRY AREA RIGHT . SIDE FLOOR PANEL 222FF IAW A319 SRM 51-72-11-911-001. (0984107).