What was found
(LOG 1002166) GOUGES WERE FOUND ON HOLES (5EAS) VERTICAL PRESSURE DECK WEB, VERTICAL STIFFENERS AND ATTACH ANGLE AT RH SIDE AS FOLLOW: HOLE # 1 GOUGE AT 6 O CLOCK POSITION ON ATTACH ANGLE AND PRESSURE DECK WEB, HOLE #2 GOUGE AT 5 O CLOCK POSITION ON ATTACH ANGLE AND PRESSURE DECK WEB, HOLE #3 GOUGE AT 7 O CLOCK POSITION ON ATTACH ANGLE AND PRESSURE DECK WEB, HOLE #4 GOUGE AT 5 O CLOCK POSITION ON PRESSURE DECK WEB AND VERTICAL STIFFENER AND HOLE #5 GOUGE AT 1 O CLOCK POSITION ON PRESSURE DECK WEB AND VERTICAL STIFFENER. VERTICAL PRESSURE DECK WEB, VERTICAL STIFFENERS AND ATTACH ANGLE AT RH SIDE WERE REPAIRED PER ER/A 626327-14 REV. ORIGINAL.