What was found
AFT SERVICE DOOR (R2) SCUFF PLATE FASTENER HOLES 110L - 140L HAVE CORROSION. REMOVED CORROSION AND EVALUATED DAMAGED AREA ON AFT SERVICE DOOR SKIN CUTOUT, FOUND OUT OF LIMITS IAW A220 ASRP J51-21-06 AND J53-61-01. RESTORED FINISH, ALL WORK ACCOMPLISHED IAW DELTA ERA626313-14 REV. ORIGINAL. ASSOCIATED ER/A 14-626313 ADDED FOR AC 8120. (LP# 1005657)