What was found
(LOG 1031712) CORROSION ON FLOOR BEAM UPPER AND LOWER AREAS STA 947.5 FROM 6 RBL TO 6LBL AT W2. FLOOR BEAM UPPER AND LOWER AREAS STA 947.5 FROM 6 RBL TO 6LBL AT W2 WAS REPAIRED PER B 737-800 SRM 53-70-51-2R PROCEDURE 8 REPAIR 8.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
(LOG 1031712) CORROSION ON FLOOR BEAM UPPER AND LOWER AREAS STA 947.5 FROM 6 RBL TO 6LBL AT W2. FLOOR BEAM UPPER AND LOWER AREAS STA 947.5 FROM 6 RBL TO 6LBL AT W2 WAS REPAIRED PER B 737-800 SRM 53-70-51-2R PROCEDURE 8 REPAIR 8.