What was found
(LOG 1071838) CORROSION ON FLOOR STRUCTURE ANGLES (3E/A) BTW STA 260 AND STA 270 BTW LBL 11 AND RBL 11 AT FLIGHT COMPARTMENT. FLOOR STRUCTURE ANGLE (1EA) BTW STA 270 BTW LBL 11 AND RBL 11 WAS REPAIRED PER ER/A 627248-14 REV. ORIGINAL SECTION I: PERMANENT REPAIR.FLOOR STRUCTURE ANGLES (2E/A) BTW STA 260 AND STA 270 BTW LBL 11 AND RBL 11 WERE CLEANED PER DAL PS 900-1-2-2 NO. 02, AFTER CLEANING DVI ON AREA WAS PERFORMED PER B737-800 SRM 51-10-04-0G AND NO CORROSION OR OTHER DISCREPANCIES WERE OBSERVED.