CORRODED FLOOR SUPPORT Y1292 LOCATED BETWEEN FR16 TO FR20, FWD GALLEY AREA. REPLACED FLOOR BEAM Y1292 LOC. BTW. FR12 TO FR24 AT FWD GALLEY AREA IAW SRM 51-42-11 AND SRM 51-72-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORRODED FLOOR SUPPORT Y1292 LOCATED BETWEEN FR16 TO FR20, FWD GALLEY AREA. REPLACED FLOOR BEAM Y1292 LOC. BTW. FR12 TO FR24 AT FWD GALLEY AREA IAW SRM 51-42-11 AND SRM 51-72-11.