What was found
DAMAGE TOLERANCE EVALUATION (DTE) REQUIRED. ER/A 629295-14 SECTION I ISSUED FOR A FUSELAGE SKIN REPAIR AT FR 69-FR 70, S- 28R TO S-32R. SECTION I, ACCOMPLISHED DURING MSP LINE VISIT 23SEP25. FOLLOW ON ACTION IS REQUIRED. REPAIR APPROVAL IS LIMITED TO 200 FC PENDING A DAMAGE TOLERANCE ANALYSIS. FURTHER ENGINEERING APPROVAL (ER/A REVISION) IS REQUIRED FOR CONTINUED SERVICE BEYOND THE THRESHOLD. ASSOCIATED ER/A 32-629295. (LP: 1214816)