What was found
INTERMITTENT DOOR L AFT CABIN ON CLIMBOUT WITH MASTER CAUTION. R & R BOTH PROX SENSORS 23MJ/25MJ PER A330 AMM 52-71 AND ADJUSTED SENSOR CLEARANCES OPS CK GOOD. PSEU TEST PASSED NO CURRENT FAULTS. (1256974)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INTERMITTENT DOOR L AFT CABIN ON CLIMBOUT WITH MASTER CAUTION. R & R BOTH PROX SENSORS 23MJ/25MJ PER A330 AMM 52-71 AND ADJUSTED SENSOR CLEARANCES OPS CK GOOD. PSEU TEST PASSED NO CURRENT FAULTS. (1256974)