What was found
CRACK INDICATION FOUND IN HOLE 1 OF THE DOOR STOP FITTING 7 AT FRAME 1 6 RH SIDE. REPLACED INTERCOSTAL AND FASTENERS LOCATED AT LEVEL DOOR STOP FITTING 7 AT FR 15 TO FR16 RH SIDE AND FASTENERS AS PER A319 SRM 51-42-11 AND A319 SRM 51-72-11. (1283977).