What was found
DURING SERVICE CHK, WHILE PERFORMING THE EMERGENCY ESCAPE SQUIB TEST 2, THE LEFT BOTTLE INDICATOR DID NOT COME ON. T/S BOTH LIGHTS ILLUMINATE WHEN DEPRESSED, PUSHING TEST 2 SWITCH ON SQUIB TEST PANEL, ONLY R ILLUMINATES. PER FIM R/R SQUIB TEST PANEL, M32. L EMERGENCY ESCAPE REMAINED OFF. R & R LT EMERGENCY ESCAPE SLIDE INFLATOR IAW W/C 2565-4646-LH. ALL RII NOW ON W/C, ALL SQUIBS TEST NORMAL. (8017168)