What was found
EXTERNAL POWER PANEL CUT OUT DAMAGED. REMOVED INTERNAL CRACK INTERCOSTAL IAW DWG 141A0640. C/W PRI 630191-14 REV ORIG PRI REV 0. ERA 630191-14 HAS BEEN CANCELLED AND NOW WORKING OUT OF THE SRM IAW SRM 53-10 -15-2R, PROCEDURE 5 REPAIR. REMOVED EXISTING FASTENERS IN REPAIR AREA. TRIMMED BACK INTERNAL .040" DOUBLER IAW SRM 53-10-15-2R, PROCEDURE 5, FIG 202. C/W STEP D HFEC / BHEC IAW SRM 53-10, NO CRACKS FOUND. C/W BHEC IAW SRM 53-10-15-2R-5 STEP 4 (E), NO CRACKS NOTED. COMPLETED REPAIR PARTS TO 4 M IAW SRM 53-10 -15-2R-5. TREATED & PRIMED REPAIR IAW SRM 53-10-15-2R -5 TO STEP (4) (O). INSTALLED REPAIR WASHERS IAW SRM 53-10- 15-2R-5 STEP 4 P. INST REPAIR IAW SRM 53-10- 15-2R-5, STEPS 4, Q, R & S. REPAIR INSTALLED &FINISH GOOD IAW SRM 53-10-15-2R-5 STEP T. ) INSTALLED NEW INTERCOSTAL IAW BOEING DWG 141A0640.