What was found
CRACK INDICATION FOUND ON INNER CAP FR 68 RH SIDE AREA, CRACK LENGHT: 1.5 INCH, REQUESTING REPAIR DISPOSITION ADITIONAL EGINEERING DOCUMENTA TION IS REQUIRED AND REPAIR MUST BE ACCOMPLISHED PRIOR TO FURTHER FLIG HT REFER TO EM 5311-01244 AND SB A320-531491. COMPLIED WITH ER/A 630590-14AD REV. ORIGINAL MATCHES WITH ALL STEPS ON PRI 630590-14AD REV 0, PRI 630590-14AD REV 1, PRI630590 -14AD REV 2. IT HAS BEEN VALIDATED. PERFORMED REPAIR INSTRUCTIONS ON FUSELAGE FRAME 68RH AT LEVEL OF STR 22R AS PER ER/A630590-14AD REV. ORIGINAL SECTION I HAS BEEN COMPLIED WITH. APPROVED DATE: 24-NOV-25. FOR TIME CONTROLLED ITEMS SEE LOG PAGE #1320268.