What was found
CRACK INDICATION FOUND ON INNER CAP FR 68 LH SIDE, CRACK LENGHT = 1.0 INCH APPROX. REQUESTING REPAIR DISPOSITION ADITIONAL EGINEERING DOCUME NTATION IS REQUIRED AND REPAIR MUST BE ACCOMPLISHED PRIOR TO FURTHER F LIGHT REFER TO EM 5311-01244 AND SB A320-531491. COMPLIED WITH ER/A 630588-14AD REV. ORIGINAL MATCHES WITH ALL STEPS ON PRI 630588-14AD REV 0, PRI 630588-14AD REV 1, PRI630588 -14AD REV 2. IT HAS BEEN VALIDATED. PERFORMED REPAIR INSTRUCTIONS ON FUSELAGE FRAME 68LH AT LEVEL OF STR 22L AS PER ER/A630588-14AD REV. ORIGINAL SECTION I HAS BEEN COMPLIED WITH. APPROVED DATE 26-NOV-25. FOR TIME CONTROLLED ITEMS SEE LOG PAGE #1322891.