What was found
VERTICAL STABILIZER RH PANEL DELAMINATION FROM FUSELAGE 109 INCH AND FROM FWD EDGE 14 INCH. DAMAGED AREA REPAIRED PER B767-400 SRM 55-30-01 -2R-1 AND SRM 51-70-10 (1333457)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
VERTICAL STABILIZER RH PANEL DELAMINATION FROM FUSELAGE 109 INCH AND FROM FWD EDGE 14 INCH. DAMAGED AREA REPAIRED PER B767-400 SRM 55-30-01 -2R-1 AND SRM 51-70-10 (1333457)