What was found
UPPER CABIN, FS 1681 FLOORBEAM UPPER SURFACE, CORROSION, LEFT OF CENTER GOING OTBD APPROX 20 INCHES INCLUDING SCREW HOLES. REMOVED CORROSION AT UPPER CABIN STA 1681 FLOORBEAM, FOUND TO BE OUT OF LIMITS. REMOVED DAMAGE AND REPAIRED FLOORBEAM IAW SRM 53-00-51 AND SRM 53-60-51-2R-2. (1343705)