What was found
(LOG 1342041) BS 947 FLOORBEAM HAS DEEP CORROSION UNDER LAVATORY FITTING, LBL 24. REMOVED DAMAGED SECTION OF FLOORBEAM, FABRICATED, LOCATED, DRILLED, AND INSTALLED REPAIR PARTS IAW SRM 53-70-51-2R-5 AND SRM 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
(LOG 1342041) BS 947 FLOORBEAM HAS DEEP CORROSION UNDER LAVATORY FITTING, LBL 24. REMOVED DAMAGED SECTION OF FLOORBEAM, FABRICATED, LOCATED, DRILLED, AND INSTALLED REPAIR PARTS IAW SRM 53-70-51-2R-5 AND SRM 51-40-02.