What was found
LOWER SILL, LOWER CHORD CORRODED IN MULTIPLE AREAS. AFT OF CARGO DOOR CUTOUT. BLENDED AREAS MINIMUM REMAINING THICKNESS 0.153 AND IS OUT OF LIMITS IAW SRM 53-60-15, REPAIRED DAMAGE PER ERA 630682-14. (1352869)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LOWER SILL, LOWER CHORD CORRODED IN MULTIPLE AREAS. AFT OF CARGO DOOR CUTOUT. BLENDED AREAS MINIMUM REMAINING THICKNESS 0.153 AND IS OUT OF LIMITS IAW SRM 53-60-15, REPAIRED DAMAGE PER ERA 630682-14. (1352869)