What was found
FUSELAGE FRAME IS DENTED AT BS 500E, BETWEEN STR 25RT AND 24RT. PERFORMED FRAME REPAIR AT BS 500E BETWEEN STR 23R TO STR 25R, AT FWD CARGO. PER B-737 900 SRM 53-30-07-2R-2 STEP 4 A, B, AND C.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FUSELAGE FRAME IS DENTED AT BS 500E, BETWEEN STR 25RT AND 24RT. PERFORMED FRAME REPAIR AT BS 500E BETWEEN STR 23R TO STR 25R, AT FWD CARGO. PER B-737 900 SRM 53-30-07-2R-2 STEP 4 A, B, AND C.