What was found
IN REFERENCE TO NRC 437 WIP 7, (UT) MEASUREMENT THICKNESS WAS ACCOMPLISHED ON WEB SURFACE (DECK PLATE) BTW STA 1681.8 AND RBL 47 AT W4, THEREFORE IT'S OUT OF LIMITS PER B757-200 SRM 53-60-51-1A PROCEDURE 2 ALLOWABLE DAMAGE 2. PAR. 2. C. TABLE 101. DETAIL III. TABLE 102. CORROSION LEVEL 2: DECK PLATE BTW STA 1681.8 AND RBL 47 AT W4 WAS REPAIRED PER B757-200 SRM 53-60-51- 2R REPAIR 2 ALTERNATIVE II. (1392384)