What was found
IN REFERENCE TO NRC 437 WIP 5, : (UT) MEASUREMENT THICKNESS WAS ACCOMPLISHED ON WEB SURFACE (DECK PLATE ) BTW STA 1681 AND LBL 52 AT W4, IT'S OUT OF LIMITS PER B757-200 SRM 53-60-51-1A PROCEDURE 2 ALLOWABLE DAMAGE 2. PAR. 2. C. TABLE 101. DETAIL III. TABLE 102. SUMMARY OF NRC 00688, CORROSION LEVEL 2: DECK PLATE BTW STA 1681 AND LBL 52 AT W4 WAS REPAIRED PER B757-200 SRM 53-60-51-2R PROCEDURE 2 REPAIR 2, ALTERNATIVE II. (1395340)