What was found
CONFIRM DT EVALUATION FOR POSSIBLE FCS REPAIR EXTERNAL SKIN LOCATED BTW FR 61 TO FR 62 ALONG STR 44 LOWER FUSELAGE (REFERENCE DOC NUMBER AA. PERFORMED DVI EXTERNAL SKIN LOCATED BTW FR 61 TO FR 62 ALONG STR 44 LOWER FUSELAGE ASPER SRM 53-00-11-300-029 RECHECK REQUIREDAT THE FIRST INSPECTION THRESHOLD SHOULD BEGIN AT REPAIR INSTALLATION DATE 14- MAY-10 AT 21,200 FC / AND 42,400 FH ANDSUBSEQUENT INSPECTION AT INTERVALS OF 2,200 FC / 4,400 FH ASPER SRI 53-00-11-205-017 TABLE 002 JOB COMPLETE.WORKING HIGHER PRIORITY MAINTENANCE. NOTE SRM 53-00-11-300-029 HAS BEEN SUPERSEDED AND FOLLOW ON REQUIREMENTS SHOULD REFERENCE THE APPLICABLE TASK ON SRM 53-41- 11-205-146. (LP: 1955840)