PRE-DEPARTURE UPON USING APU BLEED FOR ACFT, WE EXPERIENCED MILD FUMES CONTINUED FOR 1 MINUTE. FOUND APU IGV ACTUATOR LEAKING FUEL, REPLACED APU IGV ACTUATOR IAW AMM 49-23-51 AND PERFORMED APU WASH. (LP 8062337)