What was found
FUSELAGE DENT BETWEEN BS 620 - 640, STRINGERS 15L-17L. REMOVED SKIN SECTION WHERE DAMAGE WAS LOCATED IAW SRM 53-30 -01-2R-2. PERFORMED HFEC OF CUTOUT & BHEC OF OPEN FASTENER HOLES, NO DEFECTS NOTED IAW SRM 53-30-01-2R-2. PERFORMED DVI OF STRUCTURE AROUND CUTOUT AREA. NO DEFECTS NOTED IAW SRM 53-30-01-2R-2. DRILLED ALL REPAIR PARTS IAW SRM 53-00- 01-2R, PROCEDURE 2, REPAIR 2. VERIFIED THAT SB 757-53A0092 HAS BEEN COMPLIED WITH IAW AA MANAGEMENT. TREATED AND PRIMED REPAIR PARTS IAW SRM 53-30-01 -24-2. INSTALLED PERMANENT REPAIR, CATEGORY B. IAW SRM 53-30-01-2R- 2. FILLET SEALED GAPS & APPLIED CORROSION INHIBITING COMPOUND IAW SRM 53-30-01-2R-2. RESTORED FINISH IAW AMM 51-21-10. (1408381)