What was found
CRACK INDICATION ON FRAME 2 WINDSHIELD CENTER POST LOWER NODE RH SIDE POCKET INTERNAL AREA, AT LOWER INBOARD RADIUS, CRACK DIRECTION IS HORIZONTAL, CRACK LENGTH IS 0.375 INCH, AD 2020- 17-03 / WORKCARD 5311-0122 6-01. COMPLIED WITH ER/A 631326-14AD REV. ORIGINAL MATCHES WITH ALL STEPS ON PRI 631326-14AD REV 0, PRI 631326-14AD REV 1, PRI 631326-14AD REV 2. IT HAS BEEN VALIDATED. PERFORMED REPAIR INSTRUCTIONS ON CENTER POST LT & RT WINDSHIELD FRAME IAW ER/A631326-14AD REV. ORIGINAL (LP 1429786)