What was found
CORROSION ON THE FLOOR SUPPORT, -Y254, AROUND HOLES BTW FR 16 - 20 IN THE FWD GALLEY AREA. REPLACED THE FLOOR SUPPORT IAW SRM 51-42-11, SRM 51-72-11, AND DWG D53111462.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON THE FLOOR SUPPORT, -Y254, AROUND HOLES BTW FR 16 - 20 IN THE FWD GALLEY AREA. REPLACED THE FLOOR SUPPORT IAW SRM 51-42-11, SRM 51-72-11, AND DWG D53111462.