What was found
AFTER THICKNES MEASUREMENT ON LT CUSP WEB BTW BS 332 - 351, BS 446 - 465, BS 522 - 579, BS 813 - 832, BS 889 - 908, & BS 908 - 927. REWORKED AREAS ARE OUT OF LIMITS IAW SRM 53-00-55-1A, PARA 4A, FIG 101. REPAIRED IAW SRM 53-00-55-2R, PROCEDURE 4, & LT CUSP WEB BTW BS 889 - 908 WAS FABRICATED & REPLACED IAW DWG 9910151, REV BV, SRM 51-41-05-0G, & SRM 51-41-02-0G. (LP 1452687)