What was found
DURING MEASURE ENGAGEMENT BTW THE GIRT BAR SLIDER WITH FWD FLOOR FITTING FOUND THERE IS NO MINIMUN ENGAGEMENT WITH TOOL GO / NO GO AT 2R DOOR , IN REFERENCE TO AMDS 2561-01257-01D STEPS 12. GIRT BAR OF 2R DOOR WAS REPLACED PER B757- 300 AIPC 25-66-05-05 AND GIRT BAR OF 2R DOOR WAS VERIFIED AND ADJUSTED PER AMDS 2561-01257-01D. (1456928)