What was found
CORRODED FLOORBEAM LOCATED BTW FR 18 - FR 20, -Y 254 AT FWD GALLEY AREA. REPLACED FLOORBEAM, FWD GALLEY AREA IAW SRM 51-42-11, SRM 51-72-11, & DWG D53111462. (LP 1464261)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORRODED FLOORBEAM LOCATED BTW FR 18 - FR 20, -Y 254 AT FWD GALLEY AREA. REPLACED FLOORBEAM, FWD GALLEY AREA IAW SRM 51-42-11, SRM 51-72-11, & DWG D53111462. (LP 1464261)