What was found
CORROSION FLOOR SUPPORT -Y1162.5 LOCATED BTW FR 68 TO FR 69 AT AFT GALLEY AREA (SSI 534147). REPLACED FLOOR SUPPORT -Y1162.5 AND FASTENERS LOC FR68 TO FR 69 AFT GALLEY AREA AS PER A319 SRM 51-42-11, A319 SRM 51-72-11, DWG: DWG D53472780 RELEASE DATE: 26/APR/18 ISSUE: K, TOOK MEASURE ARE L=0.298 INCH W= 0.187 INCH D= 0.027 INCH. SEE INDIVIDUAL SIGN OFF ORNRC 40/260. (LP: 1469446)