As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CORRODED FLOOR PANEL SUPPORT BETWEEN RBL 23 AND RBL 43.2 AT FR 76. REMOVED DAMAGED SUPPORT AND INSTALLED NEW FLOOR SUPPORT AT FR 76 -78 RBL 39" IAW BOMBARDIER DRAWING# PL C01342700 AND A220ASRP BD500-A-J51-42-06-00AAA-078A-A. (LP# 1477333)