What was found
MISSING MATERIAL FLOOR BEAM LOCATED BTW FR 20 TO FR 21 AND - Y 250 AT FWD GALLEY AREA. REPLACED FLOOR BEAM -Y189 AND FASTENERS LOCATED BTW FR20 TO FR24 AT FWD GALLEY AREA AS PER A319 SRM 51-42-11, A319 SRM 51-72-11 AND DWG D53111406 RELEASE DATE: 20/DEC/96 ISSUE: C00 AND DWG D53111364 RELEASE DATE: 23/JUL/92 ISSUE: B00. TOOK MEASURES OF EXISTING REWORKS AREA ARE, P1: L: 31.31 MM (1.27) IN, W: 27.13 MM (1.068) IN, D 1.20 MM (0.047) IN:, P2, L:, 31.40 MM (1.200) IN W: 27.13 MM (1.068) IN, D: 1.12 MM (0.044) IN, SEE INDIVIDUAL SIGN OF ON ORNRC 33/220 RII INSPECTION COMPLETE. AE351QC. (LP: 1477761)