CORROSION FLOOR SUPPORT -Y1162.5 LOCATED BTW FR 68 TO FR 69 AT AFT GALLE Y AREA (SSI 534147). REPLACED FLOOR SUPPORT - Y1162.5 LOCATED BTW FR 68 TO FR 69 AT AFT GALLEY AREA IAW SRM 51-42-11 AND SRM 51-72-11 AND DWG D53472189, DWG D53472089, DWG D53474250. MEASURES OF CORROSION ON FLOOR SUPPORT ARE P NR 1 L: 0.900 INCH W: 0.578 INCH D: 0.044 INCH P#2 L:1.500 INCH W:0.744 INCH D: 0.032 INCH. (LP: 1481096)