What was found
CRACK INDICATION ON FRAME 2 OF WINDSHIELD CENTER POST LOWER NODE, ATTACHME NT POCKET LT SIDE, INBD FLANGE, FROM UPPER TENSION BOLT, CRACK LENG TH IS 0.120, CRACK DIRECTION IS 2 OCLOCK. AD 2020-17-03 / WORKC ARD 5311-01226-01. COMPLIED WITH ER/A 632195-14AD, REV ORIGINAL. MATCHES WITH ALL STEPS OF PRI 632195-14AD REV 0 AND REV 1, RECHECK IS REQUIRED FOR AREA 2 WITHIN 58,696 TFC AND AREA 3 THE REPAIR IS TIME LIMITED TO 91,696 TFC FOR TIME CONTROLLED ITEM.