As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AD. A.A. IN REF AMDS 2560-01492-0101 STEP 2: ENGAGEMENT DIMENSION LESS THAN 0.37 INCH ON FWD GIRT BAR SLIDER AT L2 DOOR. SPRINGS ON GIRT BAR SLIDER DOOR 2L WERE REPLACED IAW CMM 25-66-14 AND SPRINGS AGREE WITH THE SPECIFIED DIMENSIONS AND GIRT BAR INSPECTION WAS PERFORMED UNDER AMDS 2560-01492-0101 SPRINGS ARE WITHIN LIMITS. (1525585) (AIRCRAFT WAS GROUNDED)