What was found
CORROSION FLOORBEAM BTW Y1292 TO Y 1162.5 AND FR 66 TO FR 68 AT AFT GALLEY AREA (SSI 534147). REPLACED FLOORBEAM AND FASTENERS LOC Y1292 TO Y1162.5 BETWEEN FR66 TO FR68 FLOOR STRUCTURE AFT GALLEY AREA AS PER A320 SRM 51- 42-11, A320 SRM 51-72-11 AND DWG D53472000 RELEASE DATE 06-JAN- 03 ISSUE AF. MEASURE OF CORROSION IS: L: 1.850 INCH, W: 1.540 INCH, D: 0.035 INCH. SEE INDIVIDUAL SIGN-OFF ORNRC 71/260. RII INSPECTION COMPLETE. (LP: 1546149) AIRCRAFT WAS GROUNDED