What was found
CORROSION WEB FRAME 16 RH SIDE AT FWD GALLEY AREA. REPLACED WEB, LOC. BTW FR12 TO 16 RH SIDE AT FWD GALLEY AREA IAW SRM 51-42-11, SRM 51-72-11 AND DWG D53112780, & DWG D53918884. TOOK MEASURES OF CORROSION ON WEB ARE: L= 3.832IN W=1.570 IN. (LP: 1551636). AIRCRAFT WAS GROUNDED.