What was found
LEFT FLOOR CUPS WEB AREA (UPPER/LOWER SURFACES) BTW STA 876 TO 884 WITH ORIGINAL THICKNESS IS 0.020 INCH AND MINIMUM REMAINING THICKNESS IS 0.008 INCH THEREFORE IT IS OUT LIMITS. REPAIRED PER B717- 200 SRM 53-00-55 (1554104) (AIRCRAFT GROUNDED)