What was found
LEVEL 2 CORROSION FLOOR BEAM -Y1292 TO -Y1162.5 BTW FR 66 TO FR 68 AT AFT GA LLEY AREA (SSI 534147). C/A: REPLACED FLOOR BEAM -Y1292 LOC. BTW FR 66 TO FR 68 AT AFT GALLEY AREA AND FASTENERS AS PER A320 SRM 51-42-11, A320 SRM 51-72- 11AND DWG: D53472780, RELEASE DATE:26/APR/18, ISSUE:K, DWG D53472816, RELEASE DATE:18/ DEC/06, ISSUE:F.MEASURES CORROSION ARE: L=0.524 IN, W= 0.106 IN DEPTH= 0.020 IN,SEE INDIVIDUAL SIGN-OFF ON ORNRC 28/260. RII INSPECTION COMPLETE. (LP: 1564334). AIRCRAFT WAS GROUNDED