What was found
LEVEL 2 CORROSION WEB LOCATED AT FR 16 LEVEL STR 23R AT FWD GALLEY AREA. REPLACED WEB LOCATED ON FR12 TO FR16 AT LEVEL STR 23R AT FWD GALLEY AREA IAW SRM 51-72-11; A320 SRM 51-42-11, DWG D53114392 ISSUE B00, RELEASE DATE 01-FEB-19, DWG D53112781 ISSUE E00, RELEASE DATE: 07-APR-93 AND DWG D53112780 ISSUE F00, RELEASE DATE: 28-MAY-98. MEASURE OF CORROSION ON WEB ARE L:0.364 INCHES, W:0.322 INCHES. DISPLACED AND PLACED OF COAXIAL 43RT2-A ON WEB IS TO BE ACCOMPLISHED ON ORNRC 287/200. SEE INDIVIDUAL SING-OFF ON ORNRC 60/220. RII INSPECTION COMPLETE. (LP: 11573059). AIRCRAFT WAS GROUNDED