What was found
CORROSION FLOOR SUPPORT +Y1162.5 LOC. FR 68 TO FR 69 AT AFT GALLEY AREA (SSI:534147). REPLACED FLOOR SUPPORT Y1162.5 LOC.FR68 TO FR69 AT AFT GALLEY AREA AS PER SRM 51-72-11, A319 SRM 51-42-11 AND DWG D53472780ISSUE: K RELEASE DATE:26-APR-18, DWG: D53474180 ISSUE: AA RELEASE DATE: 09-SEP-24,DWG: D53474250 ISSUE: S RELEASE DATE: 07-SEP-01. MEASURES OF CORROSION WERE L: 0.105 INCH W: 0.046 INCH D: 0.052 INCH. AIRCRAFT WAS GROUNDED