What was found
LEVEL 2 CORROSION FLOOR SUPPORT -Y1292-1162.5 LOC. FR 66 TO FR 68 AT AFT GALLEY AREA. REPLACED FLOOR SUPPORT -Y1292, -Y1162.5 AND LOCATED BETWEEN FR66 TO FR68 AT AFT GALLEY AREA IAW SRM 51-42-11 AND SRM 51-72-11 AND DWG D53472816, ISSUE F, AND DWG D53472780 ISSUE K. TOOK MEASURES OF CORROSION ARE: L= 0.229 INCH, W= 0.217 INCH, D= 0.028 INCH. (LP: 1605825) AIRCRAFT WAS GROUNDED