What was found
EXISTING REPAIR FR68, INNER CAP & FR FLANGE, STRG 22 RH AT LEVEL DOOR STOP FITTING 1. CONTACT DELTA LIAISON ENGINEERING FOR ALTERNATE INSPECTION INSTRUCTIONS THAT MAY BE REQUIRED TO COMPLETE WORK CARD 5311-0124 4-02B DUE TO PREVIOUS REPAIR IN THE INSPECTION AREA. ADDITIONAL ENGINE ERING DOCUMENTATION MAY BE REQUIRED PRIOR TO FURTHER FLIGHT. INSTRUCTIONS TO LIAISON IN EARTH FOLDER "DELTA AA PROJECTS1531531115311-01244". REFERENCE EM 5311-01244-02B AND SB A320-53-1491. (LP: 1619470, AIRCRAFT WAS GROUNDED)