What was found
CRACK INDICATION ON FRAME 2 WINDSHIELD CENTER POST LOWER NODE ATTACHM ENT AREA CONTINUITY FITTING RH SIDE, CRACK LENGTH IS 0.200 INCH, AD RE LATED, AA 5311-01226, AD 2020-17-03, WORK CARD 5311-01226-01. REQUESTI NG REPAIR DISPOSITION. REPAIR MUST BE ACCOMPLISHED PRIOR TO FURTHER FL IGHT. IN COCKPIT (1EA). COMPLIED WITH ER/A 633308-14AD REV. ORIGINAL APPROVED DATE 27- MAY-26 MATCHES WITH ALL STEPS ON PRI 633308-14AD REV. 0; REV. 1; ITHAS BEEN VALIDATED. PERFORMED REPAIR INSTRUCTIONS ON FRONT WINDSHIELD CENTER POST LOWER ATTACHMENT, CONTINUITY FITTINGS LH ANDRH AS PER ER/A 633308-14AD REV. ORIGINAL SECTION I HAS BEEN COMPLIED WITH. SEE LOG PAGE 1616599 FOR TIME CONTROLLED ITEMS SECTION II. SEE INDIVIDUAL SIGN-OFF ON ORNRC 132/200 RII INSPECTION COMPLETE. (LP: 1628865, AIRCRAFT WAS GROUNDED)