What was found
DID NOT PASS OPS TEST OF DOOR DAMPER ON PASSENGER CREW DOOR 832. REMOVED DOOR DAMPER FROM PASSENGER CREW DOOR 832 IN UNSERVICEABLE CONDITION JOB IN PROGRESS. REPLACED UNSERVICEABLE DOOR DAMPER PN FE174-004 SN NO869 FOR NEW DOOR DAMPER PN FE240-006 SN RFM29991 ON PASSENGER CREW DOOR 832AS PER A320 FAM AMM 52-13-14-000-001-B AND AS PER A320 FAM AMM 52-13-14-400-001-B. SEE INDIVIDUAL SIGN OFF ON ORNRC 10/260. RII INSPECTION COMPLETE. (LP: 1638089, AIRCRAFT WAS GROUNDED)