As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DIVERTED TO RDU DUE TO LEFT ENGINE GENERATOR FAIL AND SUBSEQUENT APU AUTO SHUTDOWN. FOUND LT IDG OIL COOLER LINE LEAKING. REPLACED LINE AND LT IDG. LEAK AND OPS CHECK GOOD. NO FAULTS ON APU AND OPS CHECK GOOD. (7985735) AIRCRAFT WAS GROUNDED