What was found
LEVEL 2 CORROSION, CORROSION WEB FRAME 20 LOCATED LEVEL STR 23R AT FWD GALLEY AREA. REPLACED WEB AND FASTENERS LOC. ON FRAME 20 AT LEVEL STR 23R IN FWD GALLEY AREA AS PER A320 SRM 51-42-11, A320 SRM 51-72-11,DWG: D53114392 RELEASE DATE: 01-FEB-19 ISSUE:B00 AND DWG D53112784, RELEASE DATE: 28/MAY/98, ISUE: F00. SEE INDIVIDUAL SING-OFF ORNRC 55/220 RII INSPECTION COMPLETE. (LP: 1696674, AIRCRAFT WAS GROUNDED)