What was found
LEVEL 2 CORROSION, CENTER FITTING LOCATED BTW FR 16 TO FR 20 AT LEVEL STR 23L CUT OUT FWD GALLEY AREA. REPLACED CENTER FITTING AND FASTENERS LOC. BTW FR 16 TO FR 20 AT LEVEL STR 23L CUT OUT FWD GALLEY AREA IAW SRM 51-42-11, SRM 51-72-11 AND DWG D53112109, MEASURES OF CORROSION WERE: L=0.302 INCH W=0.606 INCHD=0.076 INCH. (LP: 1697631, AIRCRAFT WAS GROUNDED)