What was found
CONFIRM DT EVALUATION FOR POSSIBLE FCS REPAIR STRINGER 5L LOCATED BTW FR 43 - FR 45 IN PASSENGER CABIN. CONFIRMED DT EVALUATION FCS ON EXISTING REPAIR STR 5L LOC. BTW FR 43 - FR 45 IN PAX CABIN UPPER FUSELAGE, ENGINEERING CONTACTED DUE TO NOT COMPLIED WITH REQUIREMENTS REPAIR FOR MINIMUM OF 4 FASTENERS SPACING BTW OUTER FASTENER ROWS & ADYACENT REPAIR & ANY EXISTING DOUBLER REPAIR IAW SRM 51-70-20 FIGURE 003 SHEET 03. ENGINEERING PROVIDED SRM 53-00 -13-300-001. PERFORMED REPAIR INSTRUCTIONS IAW SRM 53-00 -13-300-001, PARAGRAPH 2. A RECHECK IS REQUIRED DUE TO REPAIRIS CATEGORY B INSPECTION THRESHOLD FROM TIME OF ADL/REPAIR EMBODIMENT 60000 FC OR 120000 FH IAW SRM 53-00-13-205-001, PARAGRAPH 2.A, TABLE 001.