What was found
(DALR) WHILE PERFORMING A SCHEDULED OPS CHECK OF THE PASSENGER DOOR ESCAPE SYS, THE L4 PASSENGER ENTRY DOOR FAILED TO BE OPENED BY THE EMERGENCY POWER SYS. TASK CARD DIRECTED THE MECHANIC TO ARM THE DOOR AND TURN THE INTERIOR HANDLE UNTIL THE EMERGENCY POWER SYS STARTED, THEN RELEASE THE HANDLE AND MOVE AWAY. IT FURTHER SPECIFIED THAT IF THE DOOR DID NOT POWER OPEN WITHIN THE SPECIFIED 2 TO 6 SECOND LIMIT, THE DOOR WAS TO BE MANUALLY PUSHED TO THE FULL OPEN POSITION. WHEN THE EMERGENCY POWER SYS FAILED TO ACTUATE, THIS WAS DONE, AND THE SLIDE DEPLOYED SATISFACTORILY AND FULLY INFLATED. EMERGENCY POWER RESERVOIR GAUGE PRESSURE READ ZERO WHEN INSPECTED AFTER ACTUATION, SO THE RESERVOIR EITHER (A) HAD NO PRESSURE TO BEGIN WITH OR (B) WAS SUCCESSFULLY ACTUATED, BUT THE DISCHARGED NITROGEN FAILED TO ACTUATE THE DOOR OPENING MECHANISM. FAILURE WAS SOMEWHERE IN THE DOOR EMERGENCY POWERED OPERATING SYS, WHICH CONSISTS OF A NR OF COMPONENTS. INCIDENT IS UNDER INVESTIGATION, BUT AT THIS TIME WE ARE UNABLE TO POINT TO THE SPECIFIC COMPONENT THAT CAUSED THE FAILURE. THIS REPORT IS BEING FORWARDED SUCH AS IT IS TO ENSURE COMPLIANCE WITH THE 96 HOUR FROM DISCOVERY TIME LIMIT; HOWEVER, MORE INFORMATION IS FORTHCOMING AS THE SYS IS INVESTIGATED.